Universal Temperature Differential Controller
 
SOLARCONTROLLER

USDT 2004 controller has following functions:

  • 3 inputs for temperature sensors
  • 1 input for flow rate measurement or start at low insolation
  • BTU meter with or without flow rate measurement
  •  Adjustable hysteresises on all inputs
  • Adjustable (0 oF to 41 oF) frost protection
  • Adjustable (200 oF to 299 oF) overheating protection
  • Adjustable (4.1 oF to 99 oF) temperature difference ∆T
  • Manual pump operation for system testing
  • Exchangeable 3.15 A system protection fuse
  • System diagnostic and status displays
  • Collector sensor surge protection
  • Digital display of all parameters

NOTE: The information presented in this page is for guidance only - no part of this may be used for any agreement, whether expressed or implied, or to form any contract. THERMO TECHNOLOGIES reserves the right to change specifications and prices without prior notice.

Universal Differential Controller

USDT 2004 is an advanced temperature differential controller. It is a microprocessor based temperature controller that regulates solar water heating systems and records collected energy in KWh units.

The standard unit includes two thermistor sensors. The system diagnostics are powerful and acute; they display potential system problems such as sensor or pump failures.

DICOUNTINUED


The USDT 2004 monitors and displays supply and return temperatures. When the supply temperature exceeds the return temperature by a programmable temperature difference (∆T), an internal relay can power a ¼ HP pump or an auxiliary relay.
To avoid overheating the controlled system, the pump stops when the supply temperature reaches a programmable maximum temperature (TMAX).  Frost or cooling protection is regulated through return temperature monitoring. Regardless of the temperature difference (∆T), the pump runs when the return temperature is below a programmable minimum temperature (Tmin).  The system offers an adjustable temperature hysteresis to avoid pump cycling.


Power Connection
  • Power supply 120 V AC
  • Maximum load 3.15 A
  • Phantom load max. 2 W
  • A surge arrester at the collector sensor reduces lightning damages to the controller internal electronics 

Sensor Characteristics

  • The unit is supplied with two thermistor sensors
  • Sensor cables can be extended up to 500 feet using standard two wire cables
  • Collector sensor is supplied with a weather resistant terminal box and EMI impedance protector