Boiler Temperature Differential Controller
 
BOILERCONTROLLER

USDT 2005 can serve as a boiler temperature differential controller. It is a microprocessor based temperature controller that regulates solar water heating systems.  A green LED illuminates when the supply temperature exceeds the return temperature by a programmable temperature difference (∆T.) Controller and pump are protected by a 3.15 A fast fuse.

To avoid overheating the storage tank, the pump stops when the return temperature reaches a programmable maximum temperature (TMAX). 

 

NOTE: The information presented in this page is for guidance only - no part of this may be used for any agreement, whether expressed or implied, or to form any contract. THERMO TECHNOLOGIES reserves the right to change specifications and prices without prior notice.

USDT 2005 is a microprocessor based temperature differential controller. In the boiler control mode (L) the boiler circulation pump runs only when boiler temperature at S1 location is higher than the minimum set point dialer and the ∆T condition is satisfied.  
A green LED illuminates when the programmed conditions are satisfied and the pump is running. Controller and the pump are protected by a 3.15 A fast fuse.

Note: The maximum temperature dialer (max) serves as the minimum starting temperature.  User must change the switch position on the back of the circuit board to use the USDT 2005 as a boiler controller. 

The system diagnostics displaY sensor failures. The suggested retail price for a controller and two sensors is $ 139.00.

General

Pump A1 (ON) only  S1 > max & S1 > (S2 + diff)

  • Adjustable Delta T (∆T) differential from 4  to 24 degrees Fahrenheit (F)

  • Manual override of outputs for system testing

  • Adjustable minimum boiler temperature from 100  to 200 degrees Fahrenheit

  • Unit accepts both thermistor and PT 1000 sensors

  • Alarm indicator for warning in case of sensor failure

  • Status screen for indication of the current state of  the pump

Sensor Characteristics

  • The unit is supplied with two thermistor sensors
  • Sensor cables can be extended up to 500 feet using standard two wire cables
  • Collector sensor is supplied with a weather resistant terminal box and EMI impedance protector

Power Connection  
  • Power supply 120 V AC
  • Maximum load 3.15 A (75 W)
  • Phantom load max. 2 W
  • A surge arrester at the collector sensor reduces lightning damages to the controller internal electronics
  • The unit is supplied with two thermistor sensors
  • Sensor cables can be extended up to 500 feet using standard two wire cables
  • Collector sensor is supplied with a weather resistant terminal box and EMI impedance protector